BOP Control
System for drilling is equipped with the
following: |
|
11-gallon, 3,000-psi WP
accumulator bottles, ASME-coded and stamped (Additional certifications, DNV,
TUV, etc., are available upon request.)
Electronic motor-driven triplex pump assembly with motor starter and
automatic switch-all explosion-proof
Fluid control manifold with air cylinders for remote controls
60:1 ratio air-operated pumps with air automatic pressure switch
Glycerine-filled, panel-mounted gauges (extra heavy-duty mud
pump-type gauges available)
Hydraulic over air pressure transmitters to convert critical
hydraulic pressures to low-pressure air signals to be transmitted by the control
air hose bundles to the remote panels
Fail-safe, air motor-driven, pressure-reducing and -regulating valve
(with manual override) to control hydraulic pressure to annular-type BOP |
 |
|
Model SSC240-3S11. BOP control units
are available in all sizes and can be equipped with low air pressure, low
fluid level, low accumulator pressure, and explosion-proof alarm
systems. |
|
 |
|
Model SSB200-3S11. BOP control system
designed for well snubbing
operations. |
|
 |
|
BOP control systems with skidded bottle
rack and pump |
|
Remote Control Panels
Stewart & Stevenson's
remote control panels are designed to meet the customer's requirements. They
range from stand-alone or wall-mounted styles with air or electric indication;
graphic overlays; explosion-proof cabinets and meeting specified third-party
requirements. |
|
Choke Manifold Valve Control Panels
Designed for remote control of choke manifold hydraulic-actuated
valves
Wall-mounted Panels
Designed to be used as driller's station remote panel or auxiliary
panel
Stand-alone Panels
Air-operated panels for driller's station remote panel or auxiliary
panel
Diverter Control Panels
Designed to meet the specific requirements of the customer's diverter
system |
 |
|
Choke manifold valve control
panel |
|
 |
|
Driller's panel, air pumps, waterproof
S.S., electrical remote panel, certified to DNV specifications |
|
|
 |
 |
 |
|
Model APEP09BRT. Electrically
operated |
Diverter
Panel |
Model DPAG06BRT. Air-operated remote
control panel for driller's
position |

Model DPAG07BRT. Snubbing remote
control panel, bracket- or wall-mounted
|
|
HP
Test Pumps and Recorders
Stewart & Stevenson's
Petroleum Equipment Division provides a complete line of high-pressure test
pumps for testing blowout preventer stacks, Christmas trees, choke and kill
lines and other types of equipment. Several configurations of these units are
offered, such as unit-mounted, skid-mounted, self-contained and portable, with
ranges up to 30,000 psi. |
|
 |
 |
|
Model SST 10,000G. High-pressure test
unit |
Model SSR-15. 15,000 psi chart
recorder |
|
Crown Block Safety System
Model 125 Crown Block
Safety System, manufactured by Stewart & Stevenson's Petroleum Equipment
Division, is used to prevent the collision of the traveling block with the crown
block. This system senses when the traveling block is within a preset distance
of the crown block. It disengages the clutch, then simultaneously applies the
brakes to the drawworks.
This device is critical to
the safety of rig personnel.
|
 |
|
Crown Block Safety System |
|
Item |
Description |
Part
No. |
Quantity |
|
|
Standard Crown Block
Safety System |
125-0010 |
1 |
|
1 |
Track |
125-0001 |
1 |
|
2,
3 |
Short* Toggle Valve
Assembly |
014-1000 |
1 |
|
4, 5, 8 |
Clutch Assembly |
-- |
1 |
|
6 |
Air Cylinder
Assembly |
020-0650 |
1 |
|
7 |
Bracket (furnished with Air
Cylinder Assembly) |
-- |
-- |
|
9 |
Air Relay Valve |
014-3000 |
1 |
|
10 |
3-Way Valve |
018-2150 |
1 |
|
11,
12 |
Tee (furnished on
request) |
-- |
-- |
|
Assembly |
50-foot Hose with Fittings
and Connectors |
-- |
1 |
|
13 |
Short Toggle Valve
(furnished on request) |
014-1100 |
|
|
*A long retractable toggle
valve is also available and is furnished on request (Part No. 014-1200). |
|
Specification Criteria
|
Specification
Criteria Available for Equipment |
|
Electrical Equipment |
API RP 500B, API RP 14F,
NEC Article 500, NFPA 476, UL, CSA, FM, NEMA, CENELEC, BASEEFA, British
Standards |
|
Pressure Vessels |
ASME Section VIII, Division
1 |
|
Pressure Piping |
ANSI B.31.3 British
Standards |
|
Welding |
AWS D1.1 and ASME Section
XI |
|
Corrosion Protection |
Steel Structures Painting
Council (SSPC) |
|
BOP accumulator control unit for
offshore application certified to DNV
specifications |
|
 |
 |
 |
|
Self-contained BOP control
system |
BOP accumulator control unit for
minute-man control system |
Air-operated BOP control
system |
|
|